Materials and Methods

Technical products were supplied by the Research Institute of Agrochemical Technology
Formulation product is Orthene® 75 SP (Chevron Chemical company, France)

GLC information:
  • Gas Chromatograph Fractovap, model 2400T (C. Erba, Milan) equipped with FID
  • Speedomax XL 681 recorder (Leeds and Northrup, USA)
  • A glass column 60x0.25 cm (i.d.) was packed with 3% of Reoplex-400 (Merck,GFR) on Gas-Chrom Q 100/120 mesh (С. Erba, Milan)
  • Column temperature was 448 К and the injection port and detector temperatures were 458 K
  • Gas pressures were: carrier gas nitrogen 85 kPA, hydrogen 60 kPa, oxygen 50 kPa

Internal standard:
  • Methyl 2,4,5-trichlorophenoxyacetate (2,4,5-T methyl ester)

Solvent:
  • Anal. grade chloroform

Chloroform calibration solution for acephate:
  1. 40 mg of the internal standard (2,4,5-T methyl ester)
  2. 100 mg of the standard acephate

Technical chloroform solution for acephate:
  1. 40 mg of the internal standard (2,4,5-T methyl ester)
  2. 120 mg of the technical acephate

Formulated chloroform solution for acephate:
  1. 40 mg of the internal standard (2,4,5-T methyl ester)
  2. 130 mg of the formulated acephate

Chloroform calibration solution for 0,0dimethyl N-acetylphosphoroamidothioate:
  1. 200 mg of the internal standard (2,4,5-T methylester)
  2. 220 mg of 0,0-dimethyl N-acetylphosphoroamidothioate standard

Technical chloroform solution for 0,0dimethyl N-acetylphosphoroamidothioate:
  1. 200 mg of the internal standard (2,4,5-T methyl ester)
  2. 250 mg of the technical product

Stationary phases and solid supports used:

  1. NPGS,
  2. EGS,
  3. DEGS,
  4. THEED,
  5. Reoplex-400,
  6. Chromosorb W-HP, Chromosorb G-HP, Gas-Chrom Q