Results and discussion



The optimum chromatographic conditions were obtained by testing them using different stationary phases and solid supports stated above. After the evaluations, the results show that using 3% Reoplex-400 as the stationary phase together with Gas-Chrom Q 100/200 mesh give peaks of best symmetry. G.L.C analysis of technical and formulated (Orthene®) Acephate were conducted using O,O-dimethyl N-acetylphosphoroamidothioate as the positive control for identification of impurities. The  resulting chromatographs are are follows.
  • Fig.1: Technical Acephate (peak no .3)
  • Fig.2: Formulated Acephate (peak no. 4)
  • Fig.3: Technical  O,O-dimethyl N-acetylphosphoroamidothioate (positive control for Impurity detection)

The above analysis was carried out using 4 other Orthene® samples and 3 other O,O-dimethyl N-acetylphosphoroamidothioate synthetic samples. The results are then summarized and analysed to assess the relative error of the weight of Acephate and its impurities in the product.



The results show that there are indeed differences in the percentage of Acephate compound in all samples of the product. The same goes for the identification of O,O-dimethyl N-acetylphosphoroamidothioate from the synthetic mixture samples. However, the calculated relative errors for all the analysis of the samples are not more than 2% suggesting high reproducibiity which proves G.L.C as the most applicable method for Acephate determination and its identification of impurities.

The accuracy of the G.L.C was analysed using synthetic mixtures prepared in the laboratory with known amount of the standard compound to emphasize further the reproducibility of the method.

Preparation of Technical Acephate:
О, О -dimethyl phosphoroamidothioate  -acetylation→ N-acetylphosphoroamidothioate -Isomeration→ Acephate

The technical mixture samples contain equal concentrations and volumes of internal standards and Acephate to the formulated product analysed.
Almost identical peaks were obtained which again display the efficiency of G.L.C for identifying. Complete resolution of the analyzed mixture to the individual peaks enables direct identification and/or determination of impurities of different toxicological significance.

To conclude the findings, statistical evaluations of the the G.L.C analysis of was summarized as follows.

The results and the statistical evaluation show high precision with low variance and accuracy of the О, О -dimethyl N-acetylphos­phoroamidothioate impurity determination. This supports the method as a suitable approach for analytical control of the technological process in acephate production.

0 comments:

Post a Comment

 
Copyright © 2010 Acephate! The amazing insecticide. All rights reserved.
Blogger Template by